nanaxhalo.blogg.se

Atwood Hydro Flame Furnace Thermostat
atwood hydro flame furnace thermostat













  1. Atwood Hydro Flame Furnace Thermostat How To Be Sure#
  2. Atwood Hydro Flame Furnace Thermostat Update On The#
  3. Atwood Hydro Flame Furnace Thermostat Free Ground Shipping#

The screen is designed to keep out unwanted pests like nesting insects, small rodents, things like that. Its made from a heavy duty stainless steel construction. Today were gonna be taking a look at the Valterra bug screen for Atwood Hydro Flame RV furnace vents.

Atwood Hydro Flame Furnace Thermostat How To Be Sure

Good used The first page A Humument. Differences between HYSTER-LIFT TRUCKS H60E Challenger All. But, how to be sure? Link to Dyers RV Parts and Accessories product page Are Hydro Atwood Manual Thermostat Furnace Flame DEERE. It appears from the published dimensions that the "Dometic AFMD35111 35,000 BTU Medium 12VDC Furnace" will mount the same and from the image on Dometic's website, it looks like the vent is in a similar location. The issues with the later option include form factor (physical size, location of the vent, ducting, etc.), and whether or not or painted furnace door will fit (mainly an issue with the vent location), and finally, whether it will be controlled by the existing Dometic thermostat.

Powered with 120V AC, the board sends signals to open the gas valve and emits a high output voltage that creates an ignition spark to light the burner.Description. 2.Dometic Atwood 30621 OEM Hydro Flame Furnace AFL Igniter Control Board - AC The ignition control board performs all the functions necessary to turn the furnace on and keep it running. Items 1 to 12 of 26 total. The 8516-IV is a forced-air furnace that uses a heat exchanger to.

That can be worked around easily enough. One thing I see on the Dometic products is that the LP connections are on top with a tube assy that connects at back of the unit. No responses to my question, so I guess I may be the guinea pig on figuring out what to replace the original Hydroflame 8535 III furnace with. Maybe for the best, I tell myself. Quantity 1 x.I guess I waited too long to pull the trigger on the Atwood two stage Excalibur XT, since I was unable to even find any new old stock examples. Direct Replacement For Most 12 Volt Thermostats With Heat Only Furnaces.

However, I have found one new old stock Excalibur XT two stage 25/40K BTU. They look identical, and are likely a drop in replacement. There are a few out there with the same model number except that they are a series IV, i.e. Another possibility is new old stock Excalibur (name change from Hydroflame?) there are so many model numbers which appear to have the same form factors with the LP connection on the side and the tabs which hold on the bezel for the door hinges. It looks like it must be close, but close enough? Hmm.

I may have to "adjust" the 2" utility bay duct penetrations to accommodate the depth of the unit. In measuring the space where the furnace goes, I can make it fit. It is quite a bit deeper however, apparently 23 ½". The attached pictures should make that clear. The exterior portion of it has a taper on the top and bottom, but the bulk of it is 9 ⅛" high as opposed to 7".

Atwood Hydro Flame Furnace Thermostat Update On The

I have ordered the NOS Atwood 2540 DCLP from an outfit called Tristate Surplus out of Michigan. I will post my resolutions as I go.Here is an update on the Atwood Hydroflame furnace replacement process. Decisions, decisions It would be easier if I wasn't so slammed with priority projects to get ready for an 8 to 10 month trip starting at the Quartzsite gathering. On the other hand, these are fairly simple beasts and the parts are readily available. The real difficulty is just the risk of getting a fairly expensive piece of gear without the cushion of a factory guarantee should it be DOA. I will have to fabricate new supports, but that won't not be a problem.

He stated that things were improving but that the transition to the new product lines was far from smooth. He mentioned that since Dometic had absorbed Atwood, he was working on ironing out a lot of engineering issues on Dometic's furnace offerings. She let me talk to the tech which went a long way to reassuring me about the condition of the furnace. Anyway, I spoke to a nice lady who told me that their tech goes through everything to make sure that the items are in working condition. So I called them this morning to get a feel for their operation, since this is an NOS item, there is no warm fuzzy return option (not that returning a large 45lb.

Atwood Hydro Flame Furnace Thermostat Free Ground Shipping

Additionally, the seller's website offers free ground shipping to the lower 48. If they had had the next size down (23/34K BTU), I would likely have opted for it just because the smaller physical size (matches the old one) would have required less adjustment in the furnace compartment.On a side note, buying the unit from the website as opposed to eBay, resulted in a lower total cost (probably because the seller will have no eBay or PayPal fees). I may add a couple more 2" ducts for the basement to allow for more air flow through the unit, but I am hoping that the furnace will operate on the low setting most of the time. In any case, as these LP furnaces these are relatively simple beasts and parts are still available, I decided to pull the trigger on the Atwood 2 stage 25/40K BTU furnace. Interesting tidbit that before Atwood was bought out by Dometic, Atwood developed the helium based absorption fridge that was promptly axed when Dometic acquired Atwood.

atwood hydro flame furnace thermostat

Interesting tidbit that before Atwood was bought out by Dometic, Atwood developed the helium based absorption fridge that was promptly axed when Dometic acquired Atwood. His opinion was that Atwood was a more quality oriented company than Dometic. He stated that things were improving but that the transition to the new product lines was far from smooth. He mentioned that since Dometic had absorbed Atwood, he was working on ironing out a lot of engineering issues on Dometic's furnace offerings. She let me talk to the tech which went a long way to reassuring me about the condition of the furnace.

We have an 86 GV with the front and rear Atwood furnaces. If they had had the next size down (23/34K BTU), I would likely have opted for it just because the smaller physical size (matches the old one) would have required less adjustment in the furnace compartment.On a side note, buying the unit from the website resulted in a lower total cost (probably because the seller will have no eBay or PayPal fees) as well as free shipping, saving a whopping $160 over what the buy it now price on eBay would have been.Thanks Don for the amazing thoroughness of your project. I may add a couple more 2" ducts for the basement to allow for more air flow through the unit, but I am hoping that the furnace will operate on the low setting most of the time.

It's just some sheet metal mods. Almost can't hear the flame.- Modified old Atwood faceplate to suit the Suburban. This two stage furnace, Model SHD-2542Q (25,000 and 42,000 BTU, the Q=Quiet) is very quiet on the 25,000 BTU stage. We have been using JUST the living room unit to heat the entire coach with no issues here in ColoradoHere’s the other photo. We agree with your comments about BTU needs. We will continue to watch this post and see your progress.

Not a lot, but better than nothing.- Sealed furnace to Foretravel chassis with EPDM gasketing from Frost King from Home Depot. Now there is about R6 insulation. The other six existing ducts and return duct system fit just fine.- Added insulation to front of furnace because when the furnace is not heating, there was no insulation on the front of the furnace. This was easy work for an amateur sheet metal worker like me, but it was hours of work fitting the old plenumBox to fit just right. This plenum is for three two inch ducts for the basement. It mostly fit fine.- Modified the plenum at the rear of the Atwood to better insert the Suburban.

The old Atwood used GOBS of silicon seal, which leaked and was very difficult to remove.- Added a Ecobee 4 WiFi smart thermostat, with Alexa voice interface (when connected to WiFi) with relay box and 24VAC transformer.

atwood hydro flame furnace thermostat